Diagnosing P1E00 and P0AFA on a 2013 Chevrolet Volt

A detailed breakdown of diagnosing codes P1E00 and P0AFA on a 2013 Chevrolet Volt, from 12-volt auxiliary battery drops to high-voltage cell imbalance.

P1E00 · P0AFA

2013 Chevrolet Volt

In this article

A 2013 Chevrolet Volt arrived in the bay with a permanent no-start condition and codes P1E00 and P0AFA stored in the hybrid powertrain control module. The sole symptom reported on the repair order was that the vehicle simply would not start. Our own data ranks four specific failure points for this combination of codes, starting with a surprisingly conventional component.

The Auxiliary Battery and Control Module Lockout

A degraded, discharged, or failing 12-volt auxiliary AGM battery is the most frequent trigger for code P0AFA on first-generation Chevrolet Volts. This battery is located beneath the rear cargo floor. When the 12-volt system voltage collapses below 10.5V to 11.0V during the vehicle wake-up sequence, the logic power supplying the Hybrid Powertrain Control Module 2 (HPCM2) and the Battery Energy Control Module (BECM) drops out momentarily.

As these microprocessors attempt to poll cell voltages across the high-voltage serial bus under insufficient logic voltage, they record false low-voltage data. The HPCM2 immediately flags DTC P0AFA as a Type A Secured High Voltage DTC. To protect the hybrid inverter and battery pack, the module opens the main high-voltage contactors. Once the system enters this locked state, the vehicle will not enter Ready mode even if the 12-volt battery is subsequently charged.

Clearing this state requires a dedicated scan tool procedure documented in GM Technical Service Bulletin PIC5523C. Diagnostic tests for this 85 percent probability cause include a 12-volt AGM resting voltage test, a digital conductance and CCA load test, and the HPCM and HPCM2 high-voltage secured DTC reset sequence with a parasitic capacitor discharge.

Traction Battery Cell Imbalance

Ranked as a 72 percent probability in this scenario is a high-voltage traction battery cell group imbalance or degradation. The 2013 Chevrolet Volt traction battery contains 96 cell groups connected in series to generate a nominal 360V. The HPCM2 continuously monitors these cell group voltages through the BECM.

If an individual lithium-ion pouch cell group experiences chemical degradation, high internal impedance, or excessive self-discharge, its terminal voltage can drop below the critical minimum operating limit of 2.05V to 3.00V. A code P0AFA will also set if the cell-to-cell delta exceeds 50 mV to 100 mV. As a primary safety measure to prevent copper shunting, cell reversal, and thermal runaway, the HPCM2 permanently inhibits the high-voltage precharge sequence and prevents the contactors from closing.

To verify this, technicians should perform a GDS2 96-cell voltage differential live data scan and a BECM total pack terminal voltage verification. An extended top-balancing charge cycle evaluation may also be required to assess cell health.

Manual Service Disconnect Integrity

The High Voltage Manual Service Disconnect (MSD) lever presents another high-severity failure point, ranking at 58 percent. This lever is located in the center console tunnel beneath the rear passenger trim panel. It contains an internal high-voltage cartridge fuse designed to protect the battery and drive inverter against catastrophic short circuits, along with an integrated High Voltage Interlock Loop (HVIL) contact circuit.

If this internal fuse blows open due to an electrical transient or current spike, or if the lever was removed during service and incompletely reseated, the high-voltage circuit to the power inverter module drops to zero volts. The HPCM2 senses zero voltage on the battery output terminals while monitoring logic power, flags P0AFA alongside codes P0ABC or P0ABB, and prohibits contactor engagement.

Testing involves checking the MSD lever physical seating and HVIL latch engagement. You will also need to measure the MSD internal fuse resistance and continuity using a 1000V DMM.

Module Sensing and Harness Faults

At a 42 percent probability, the fault may lie with the BECM voltage sensing circuits or internal harnesses. The BECM is mounted internally inside the high-voltage battery pack assembly. It interfaces with four internal printed circuit board sensing harnesses and multiple ribbon cables that tap each of the 96 individual cell group terminals to track voltage and temperature.

If an internal analog-to-digital converter channel fails, a printed circuit board solder joint fractures, or a voltage sense connector experiences pin fretting or corrosion, the BECM will report a false low or 0.00V reading for a cell group. This happens even if the cell itself is physically intact. The HPCM2 receives this erroneous corrupted value over the high-speed hybrid CAN bus, interprets it as a cell breakdown, and sets P0AFA with a secured contactor lockout.

Confirming this requires BECM serial data parameter validation in GDS2, followed by a BECM low-voltage power feed and chassis ground circuit voltage drop test.

Diagnostic Starting Point

When diagnosing a permanent no-start condition on a Volt with codes P1E00 and P0AFA, start by verifying the 12-volt auxiliary AGM battery beneath the cargo floor. A momentary voltage drop below 10.5V during vehicle wake-up is all it takes to trigger a high-voltage lockout. Rule out logic power issues and complete the secured DTC reset sequence before committing to high-voltage pack testing or BECM diagnostics.