Turbo, boost & air intake

Diagnosing P226321, P226322 and P004B on a Nissan Navara

A step-by-step diagnostic breakdown of codes P226321, P226322, and P004B causing intermittent power loss on a 2015 Nissan Navara NP300 II.

P2263 · P004B

2015 Nissan Navara NP300 II

In this article

An intermittent loss of power on a 2015 Nissan Navara NP300 II usually points to a handful of boost control issues, but the combination of codes P226321, P226322, and P004B narrows the field significantly. The vehicle arrived with an illuminated check engine light and a driver complaint of power dropping out randomly.

Analyzing the bypass solenoid circuit

When assessing the 2.3 dCi 190 hp engine equipped with the Continental SID 310 engine management system, code P004B points directly to pressure control circuit B. This circuit operates solenoid 2, which dictates the bypass sequence between the turbochargers.

Our diagnostic platform ranked a defective turbo bypass solenoid as the most likely culprit at 85 percent probability. An internal short in the magnetic coil or a sticking valve core causes the control unit to lose its grip on the boost curve. Because the system cannot regulate properly, it generates both P226321 for signals dropping below the minimum threshold and P226322 for over-boost pressure spikes.

The most effective starting point is a resistance check across the solenoid coil at room temperature, looking for a normal range of 10 to 25 ohms. You should also command the actuator using a diagnostic tool and verify the PWM control signal from the engine control unit with an oscilloscope.

Mechanical switch valve failures

The bi-turbo configuration on the M9T engine relies on a turbine switch valve to route exhaust flow between the high-pressure and low-pressure turbos. Our data ranked a failure in this actuator or regulation mechanism at 78 percent probability.

If the mechanical flap sticks or the vacuum actuator diaphragm develops a puncture, the transition between the two turbos fails. The valve movement falls out of sync with the request from the control unit. This mechanical delay or failure produces the exact same combination of low and high amplitude fault codes at different engine speeds.

To verify this, apply a manual vacuum pump to the actuator to check for membrane leaks. Manually actuate the linkage to feel for sticking end stops, and monitor the target versus actual position in live data during a test drive.

Wiring faults and sensor anomalies

Given that the engine logs both minimum and maximum amplitude codes simultaneously with a circuit fault, an intermittent electrical connection is a strong possibility, ranked at 70 percent. The wiring harness near the turbochargers endures severe thermal cycling and vibration.

Pin fretting or poor tension at the connector for solenoid 2 will cause momentary open circuits and subsequent voltage spikes upon reconnection. A standard wiggle test on the harness while watching live data is the standard approach, alongside a drag test on the connector pins.

A defective MAP sensor can also mimic these symptoms, ranked at 60 percent. If the internal element fails or the 5V reference drops intermittently, the output voltage jumps. Checking the zero-point calibration against the barometric sensor with the engine off will quickly validate the MAP sensor integrity.

Where to start the diagnosis

Begin with the electrical integrity of turbo bypass solenoid 2. A simple resistance measurement of the coil and a quick pin tension check on the connector will identify the most common causes of this specific code combination. If the circuit tests good, move immediately to vacuum testing the turbine switch valve actuator.

Reference pages for the codes in this article

  • P2263: what we measure for this code across real diagnostics

Start diagnosing with confidence today

Try WrenchLane and see how much time you can save, from diagnosis to repair.